HOME PAGE

SELECTOR GUIDE

LINKSWITCH® DESIGNS

TINYSWITCH® DESIGNS


TOPSWITCH® DESIGNS

DPASWITCH® DESIGNS

APPROVALS DATA

CONTACT US

EMC FILTERS
& APPS NOTES

European
Distributors


Approvals Data

Many customers have requested information on EN standards and UL listings etc.  Your feedback is important and here is the result! 

  • Meeting the EN Standards A short table for all of our standard platforms.

  • Kaschke Isolation System  UL 1446 an explanation of how we approach and comply to UL standards.

  • UL listing of materials

All of our standard parts on the website for isolation barrier transformers comply.

A step forward in removing the approvals headache for this part in your design at least.

MEETING THE EN Standards

Kaschke Platform

EN Norms

Creepage Distance

 

 

 

SP-E13/6

EN60950/EN61558

6.4mm

SP-E16/5

EN60950/EN61558

8mm

SP-E20/6

EN60950/EN61558

8mm

SP-E25-7

EN60950/EN61558

8mm

SP-E30/7

EN60950/EN61558

6.4mm std to 8mm upon request

SP-36/11

EN60950/EN61558

6.4mm std to 8mm upon request

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EN60950 and EN61558  are the standard specifications we work to as a transformer manufacturer. The following EN norms apply to the finished product but we can state that our designs will meet the standards you require. Please call to discuss the exact classification you require.

EN60 065          (Brown Goods)  EN60335 (White Goods & Battery Chargers)

Although all of the Kaschke platform parts are constructed to meet the basic standard, care must be taken to check your individual specification as the standard does change with higher working voltages and or Class levels.

As an example EN60335 Class II states a 6mm creepage. However if you require Class III then you require 8mm creepage.

Kaschke Isolation System  UL 1446

As a manufacturer of an isolation barrier for a transformer Kaschke have now been approved to meet the UL standard. The hyper link below can take you directly to the site listing.

The vast majority of Kaschke Smartpower transformers are constructed using UL listed material with our default design to KIS-03.

The KIS-03 level meets the isolation levels and to a temperature of 130 degrees C.

There are two further levels that we can also manufacture to but they are normally custom designs.

KIS-02          Potted transformers

KIS-01          155 degree C operating temperature

Please follow this link for further information
Link To UL Qualification

UL listing of materials

If you require a listing of the UL  parts within our construction. We will be glad to help and provide a spreadsheet indicating the materials used and their relevant UL number.

Certificates KIS-ME01 - KIS-ME02 - KIS-ME03

Please contact us via email on info@kaschke.co.uk









John Parkin, Cameltec Ltd, Office 1A Birch House, 80 Eastmount Road, Darlington, DL1 1LA. Company No 3375641
Tel: +44 (0)1325 360718 Fax: +44 (0)1325 360719 Mob: +44(0)7739 175476